Dual Manifold Prominent Aegis 2 Controller, 4 Metering Pumps, and 2 Metering Pumps with Degassing Heads for DLA Distribution Susquehanna PA
Agency: | DEPT OF DEFENSE |
---|---|
Level of Government: | Federal |
Category: |
|
Opps ID: | NBD00159910186636200 |
Posted Date: | Feb 28, 2023 |
Due Date: | Mar 10, 2023 |
Solicitation No: | SP330023Q0061 |
Source: | https://sam.gov/opp/007648c2a4... |
Procurement Technical Assistance Centers (PTACs) are an official government contracting resource for small businesses. Find your local PTAC (opens in new window) for free government expertise related to contract opportunities.
- Contract Opportunity Type: Combined Synopsis/Solicitation (Updated)
- All Dates/Times are: (UTC-05:00) EASTERN STANDARD TIME, NEW YORK, USA
- Updated Published Date: Feb 28, 2023 02:51 pm EST
- Original Published Date: Feb 28, 2023 02:49 pm EST
- Updated Date Offers Due: Mar 10, 2023 05:00 pm EST
- Original Date Offers Due: Mar 10, 2023 05:00 pm EST
- Inactive Policy: 15 days after date offers due
- Updated Inactive Date: Mar 25, 2023
- Original Inactive Date: Mar 25, 2023
-
Initiative:
- None
- Original Set Aside: Total Small Business Set-Aside (FAR 19.5)
- Product Service Code: 4320 - POWER AND HAND PUMPS
-
NAICS Code:
- 334512 - Automatic Environmental Control Manufacturing for Residential, Commercial, and Appliance Use
-
Place of Performance:
New Cumberland , PA 17070USA
Note: This is a Lowest Price Technically Acceptable requirement. To be considered for award, offers vendors must:
Provide the exact specifications for the Water Treatment Supplies:
Controller, Dual Manifold x 1
Dual manifold Prominent Aegis 2 controller. The controller uses conductivity, ORP and Fluorescent dye
Analog-Digital I/O: Conductivity Serial Sensor - Tower,Boiler, Condensate & Integral Flowswitch includes 1GPM integralflowswitch; Fixed Temperature Sensor Input Thermal Compensation for bothpH and conductivity displayed as oF, oC, oK; Fixed 4-20mA Current Loopinput Single Point Calibration if 4mA=0; 4 max. 4-20mA Current DCisolated; manual and auto modes, interlocking, alarm; 7 max. Manual-Inventory-inputs tracking drop counts, inventory, tank level, ppm;Communications User Interface: Keypad-LCD 5 kety tactile feedback, 3function keys, 4 line backlit w 100 mS nominal scan rate; 10 Base T,TCP/IP Ethernet LAN (optional) HTML micro web server w/user definable IPaddres, static IP; Controls for ON/OFF and Variable Frequency:Sequential Volume Setpoints; Blocking; Interlocking; 9 Biocide EventControls; System: Power 120 or 230 VAC, 50/60 Hz; Fusing for 5 ACpowered loads, 5 Amps @ 120VAC or 2.4 Amps @ 230VAC; Accessory PowerFused @ 50mA 15 - 22VDC, unregulated, thermally, auto recovery on faultcleared; Enclosure - non-metallic, NEMA 4X, 7.5"W x 11.3"H x 5.5"D or190mm W x 287mm H x 140mm D; Comply with UL Certifications
Metering Pumps x 4
Pumps will be used to maintain treatment levels and keep the cooling system safe from scale, corrosion and biological issues.
Metering Pumps with Degassing Heads x 2
Oxidizing biocide feed pumps
Prominent Beta 4b pumps, will be used to maintain treatment levels and keep the cooling system safe from scale, corrosion,and biological issues.
- ACQUISITION OPERATIONS (J7) 430 MIFFLIN AVENUE SUITE 3102A
- NEW CUMBERLAND , PA 17070-5008
- USA
- Samuel Tustin
- samuel.tustin@dla.mil
- Phone Number 7177704304
- Feb 28, 2023 02:51 pm ESTCombined Synopsis/Solicitation (Updated)
- Feb 28, 2023 02:49 pm EST Combined Synopsis/Solicitation (Original)
TRY FOR FREE
Not a USAOPPS Member Yet?
Get unlimited access to thousands of active local, state and federal government bids and awards in All 50 States.